상세스펙
  • E20:4
General
Number of powered channels 4
Total output all channels driven 2000 W
Max output voltage per channel 141 Vp / 100 Vrms
Max output current per channel 16.3 Arms
Asymmetric load operation Units are capable of delivering extra power to one channel while sending significantly less to the other. See "single ch. max" below the "all ch. driven"
Sensitivity and Maximum Output Power (all ch. driven)
2 Ω load 1 dBu: 500 W @ 45 V mode
4 Ω load 4 dBu: 500 W @ 45 V mode
8 Ω load 3 dBu: 500 W @ 70 V mode
16 Ω load 3 dBu: 500 W @ 100 V mode
70 V load 4 dBu: 500 W @ 70V mode
100 V load 4 dBu: 500 W @ 100 V mode
Sensitivity and Maximum Output Power (single ch. max)
2 Ω load 1 dBu: 500 W @ 45 V mode
4 Ω load 3 dBu: 1000 W @ 70 V mode
8 Ω load 4 dBu: 1250 W @ 100 V mode
16 Ω load 4 dBu: 625 W @ 100 V mode
70 V load 4 dBu: 1100 W @ 70 V mode
100 V load 4 dBu: 1600 W @ 100 V mode
Performance
THD (20 Hz - 20 kHz @ 1 W into 8 Ω) <0.1%
THD @ 1 kHz, 1 dB below clipping <0.05%
Signal-to-noise ratio >106 dBA
Channel separation (crosstalk) @ 1 kHz >70 dB
Frequency response 2 Hz - 40 kHz
Input impedance 20 kΩ
Input common mode rejection, CMR 50 dB
Output impedance 25 mΩ
Limiters and Gain
LIMIT switch (per channel) 3 positions: A, B and C
Max output voltage, LIMIT switch pos A (70 V)* 141 Vp / 100 Vrms
Max output voltage, LIMIT switch pos B 100 Vp / 70 Vrms
Max output voltage, LIMIT switch pos C (Lo-Z)* 63 Vp / 45 Vrms
Gain in LIMIT switch pos A (70 V)* 38.2 dB
Gain in LIMIT switch pos B 35.2 dB
Gain in LIMIT switch pos C (Lo-Z)* 31.2 dB
Level adjustment (per channel) Rear panel potentiometer, detented from -∞ to 0 dB
Connectors and Switches
Input connectors (per ch.) 3-pin detachable screw terminals, electronically balanced
Output connectors (per ch.) 2-pin detachable screw terminals
High pass filter Fixed at 50 Hz, switchable per channel
Power control Can be used to go between standby and ON, unit will also enter standby automatically after 20 min of inactivity and resume when signal is present
GPI (power control input) Contact closure type, 2-pin detachable screw terminal, controls the power state
GPO (power state output) Contact closure type, 2-pin detachable screw terminal, for external monitoring of the power state
Cooling Four fans, front to rear airflow, temperature controlled speed
Power
Nominal voltage 100 - 240 VAC
Power consumption 600 W
Standby consumption <2.5 W
Mains connector Standard IEC receptacle
Physical
Dimensions (HWD) 44 x 483 x 417 mm
Weight 7.9 kg
Finish Dark grey aluminium front and black steel chassis